ARW-3352 1500A AC/DC True RMS Clamp Meters with Inrush Current Function
This is a True RMS 1500A AC/DC Clamp Meter, 3352 is a True RMS Power Meter, which provide much more safe measurements with double molded plastic housing design. True RMS AC/DC volt-age and current measurements, 40,000 counts and 0.1% basic DC accuracy within the reach of more customers. The large LCD display with analog bargraph and backlit ensures that readings are easy to read under all circumstances.
Measuring starting current for motors, lighting, etc. is easy with Inrush current function.
All inputs are protected by EN 610101-1 CATIV 600V/CATIII 1000V.
Request information an offer on this product
| Features: |
3352 |
|
Current measurement |
AC/DC |
|
Power clamp meter |
* |
|
LCD display counts |
40000 |
|
AC True RMS |
* |
|
Display with backlight |
* |
|
Inrush current measurement |
* |
|
Max /Min, Data Hold |
* |
|
REL (Zero) Function |
* |
|
Auto Power Off |
* |
|
Low battery indication |
* |
|
Analog Bargraph / 41 seg. |
* |
|
2.16” (55mm) Jaw opening |
* |
|
NCV Detection |
* |
Specifications:
|
Function |
Max Range |
Basic Accuracy |
|
|
Current DC |
1500A |
±(2.0%+10d) |
|
|
Current AC |
1500A |
±(2.8%+10d) |
|
|
AC kW/kVA |
900.0kW |
±(3.0%+10d) |
|
|
( AC kW/kVA TRMS 0-600V, 0-1500A, 50/60Hz) |
|||
|
DC kW/kVA |
900.0kW |
±(2.5%+10d) |
|
|
( DC kW/kVA 0-600V, 0-1500A, 50/60Hz) |
|||
|
Power Factor |
0.3~1 |
±(2.5%+10d) |
|
|
Voltage DC |
1000.0V |
±(0.1%+5d) |
|
|
Voltage AC |
750.0V |
±(0.5%+5d) |
|
|
Resistance |
40.000MΩ |
±(0.5%+4d) |
|
|
Temperature |
1000ºC/1832ºF |
±(1.0%+1ºC/1ºF) |
|
|
Capacitance |
40.00mF |
±(2.5%+5d) |
|
|
Duty Cycle |
10.0 to 95.0% |
±(0.5%+2d) |
|
|
Frequency |
40.000MHz |
±(1.2%+2d) |
|
|
Inrush Current |
1500A |
±(1.5%+2d) |
|
|
Continuity check |
Buzzer sounds at 50Ω |
||
|
Diode test |
Test current 0.3mA |
||
|
Size(HxWxD) |
295mm x 100mm x 46mm |
||
|
Weight |